Quality System
Quality System & Standards
The standards, traceability and management arrangements that govern the work described on this site.
- Standard
- ISO/IEC 17025:2017
- Disciplines
- 3
Overview
Detroit CMM Calibration and Repair arranges calibration, verification and repair work for coordinate measuring machines and associated gages. Calibration is performed by laboratories accredited to ISO/IEC 17025:2017; certificates are issued under the performing laboratory's own accreditation scope. Documented procedures govern request review, method selection, result review and release, and a complaints-and-appeals process, so a quality manager can trace how a given job was scoped and who reviewed the result before it shipped.
Standards Referenced
Work described on this site is performed under ISO/IEC 17025:2017.
Accreditation named anywhere here is the performing laboratory's, and its limits are the limits of that laboratory's published scope. Measurements outside the scope are reported as non-accredited and identified on the certificate rather than quietly included. Each accreditation statement names the laboratory that holds it.
The documentation accompanying a quotation is described on the accreditation documentation page.
Metrological Traceability
Measurements reported on certificates are traceable to the SI through NIST, with reference standards and measurement uncertainty stated on the certificate itself. Before a job is quoted, the item, the required range and the tolerance being inspected are checked against the performing laboratory's published scope of accreditation, verified directly in the accrediting body's public directory. Where a decision rule or statement of conformity is required, it is agreed and documented before testing, consistent with ISO/IEC 17025:2017 and ISO 14253-1. Out-of-tolerance findings are reported with as-found data preserved, supporting a reverse-traceability impact assessment back to the prior passing certificate.
The traceability statement belongs to the measurement, not to the building. On the certificate you will find the reference standard used, its calibration status at the time, and the chain by which it reaches the SI unit. Should that reference later fail its own calibration, the intervening work is reviewed and affected customers are contacted.
Equipment and Maintenance
Equipment categories handled include bridge, gantry and cantilever coordinate measuring machines, portable articulated arms where applicable to the arm and probe configuration, granite surface plates, gauge blocks, and ring and plug gauges. Each category is verified against the standard applicable to its frame or sensor type — ISO 10360-2 and ASME B89.4.1 for bridge and gantry machines, ISO 10360-12 for articulated arms where applicable. Asset identification, due-date recall tracking and consistent equipment numbering are maintained to support audit retrieval on short notice.
Reference equipment is uniquely identified, held under controlled conditions, and recalibrated on a defined interval that is shortened when drift data justifies it. Equipment that is damaged, overloaded, or shown to give suspect results is removed from service and labeled until it has been checked and returned to use in writing.
Management System
The work sits inside a documented management system:
Controlled documents
Procedures carry issue and revision status.
Retained records
Retained for a defined period and retrievable against a certificate number.
Audit and review
Internal audit and management review run on a schedule.
Corrective action
Nonconforming work and improvement actions are tracked to closure, and their effectiveness is checked afterwards.
Impartiality and Complaints
Risks to impartiality are identified and controlled, and results are reported on their merits regardless of the commercial outcome. Complaints and appeals are a formal input to that system — the process, including the response commitment, is set out on the complaints policy page. How results should and should not be read is covered on the disclaimer page.
Compiling records for a supplier-qualification file?