CMM Calibration and Repair


Request a quote for on-site or ship-in verification.

Request a quotation

A written quotation is sent back by email.

Calibration Versus Verification

Calibration establishes the relationship between the machine's readings and a reference value, with a stated uncertainty. Performance verification confirms the machine still meets a stated specification, usually ISO 10360-2 or ASME B89.4.1.

Both terms get used loosely on the shop floor. The certificate should state which one was performed, and against which standard.

What a Visit Covers

Whether the request comes from a stamping plant's fixture room or a tier supplier's quality lab, a verification visit follows a fixed sequence.

  • 01

    Scale and reader head

    X, Y and Z scales are inspected and cleaned; reader head output is checked and adjusted.

  • 02

    Geometry

    Straightness, linearity and squareness are checked in the XY, ZX and ZY planes.

  • 03

    Length measurement error

    ISO 10360-2 E0 and E150 testing at 105 measurements across five lengths and seven positions.

  • 04

    Probing error

    ISO 10360-5 PFTU testing on a calibrated test sphere separate from the qualification reference.

  • 05

    Air bearings and drives

    Air supply, bearing preload and drive response are checked ahead of geometric adjustment.

Sequence of a Verification

  • 01

    Inspect

    Scales, reader heads and air bearings are checked before any measurement is taken.

  • 02

    Test

    Length measurement error and probing error are run against the applicable standard.

  • 03

    Adjust

    Geometric adjustment and error-map update are applied where the controller supports it.

  • 04

    Verify and certify

    As-left results are recorded and the certificate is issued.

Why Detroit CMM Calibration and Repair

  • 01

    As-found and as-left

    Both results appear on the certificate wherever adjustment occurred.

  • 02

    OEM-locked maps handled

    Error-map access is confirmed on the controller before the visit is scheduled.

  • 03

    Repair on the same visit

    Probe head, scale, air bearing and drive repair reduce a second trip.

Coverage across Michigan and the Greater Midwest

On-site scheduling and travel terms vary by location; confirm coverage and lead time when a quote is requested.